| Description | The Series "FC" flow controls are used to maintain a constant pre-determined flow in a system. They must be installed in the correct flow direction (indicated by label) to work properly. They utilize a diaphragm, which changes shape with inlet pressure changes, thus maintaining a constant flow rate. They are normally used to replace more costly flow control devices. Standard flow ranges are from 1/4 GPM to 120 GPM (.95 LPM to 454 LPM). The minimum pressure drop needed across the flow control is 15 PSI (1 Bar) in order to get the desired flow. |
|---|